3704 X-Y テーブルとワイヤーロープ防振器を用いた塔状構造物用免震テーブルの研究
近藤 洋文大亦 絢一郎下坂 陽男下田 博一
著者情報
会議録・要旨集 フリー

p. 525-526

詳細
抄録
In the previous paper, a new type of isolation table using an X-Y table and wire rope isolators was developed, and the seismic responses of the isolation table loaded with a weight or a two-degree-of-freedom furnishings model were discussed numerically and experimentally. In this paper, the seismic responses of the isolation table loaded with a three-story tower-like structure whose center of gravity is high are discussed numerically and experimentally.