The proceedings of the JSME annual meeting
Online ISSN : 2433-1325
2000.4
Conference information
Pressure Drop in a Bending Duct
Yoshihiro KONDOShinji MATSUSHITATakashi MORIYAMAShigeo OHASHI
Author information
CONFERENCE PROCEEDINGS RESTRICTED ACCESS

Pages 171-172

Details
Abstract

We have developed a method of cooling high-power-density CPU modules within a bending duct. The method uses a jet-duct system made of an air duct and axial fans. This system has slit orifices upstream from the CPU modules. Pressure drops in this system are calculated as four values : wringing loss in the chamber, friction loss in the duct, extrusion loss from the duct, and wringing loss in the slit orifice. These loss values agree with the experimentally measured losses to within an error of ±10%. The calculation showed that when the duct width is small, the wringing loss in the chamber account for the major part of the total loss.

Content from these authors
© 2000 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top