年次大会講演論文集
Online ISSN : 2433-1325
会議情報
1821 二重反転形軸流ポンプの実験的基礎研究
古川 明徳曹 銀春大熊 九州男渡邉 聡
著者情報
会議録・要旨集 フリー

p. 41-42

詳細
抄録
Demands for higher performance of axial flow pumps have led pump designers to consider the creative strategies for the new type. As a solution, contra-rotating rotors might be applied to a pump. Comparative experiment were conducted for two types, consisting of contra-rotating rotors and a rotor and a stator respectively, which were designed under the same specifications of pump head, flow rate and rotor specific speed. The measured pump performances and flow distributions are shown and the advantages of using contra-rotating type are clarified as follows. Contra-rotating type is superior in pump efficiency and cavitation performance in range of partial flow rates to conventional one though the specified pump head and maximum efficiency are not satisfied at design point in the case of contra-rotating test rotors. Results demonstrate that the rear rotor design is important to improve the pump efficiency.
著者関連情報
© 2000 一般社団法人日本機械学会