1828 トンネル換気におけるジェットファンの推力性能評価
雑賀 高中島 弘蔵瀬戸山 聡村東 浩隆三宅 学加納 竜夫
著者情報
会議録・要旨集 フリー

p. 55-56

詳細
抄録
Approximately over 1,500 Jet Fans are installed in the tunnels operated by Japan Highway Public Corporation. It is important to clearly grasp their performance and to use them for tunnel ventilation design, but this is still challenging task. It is the result of our research that the pressure raise equation based from jet fan thrust might be more suitable for designing and controlling on the conditions of the normal temperature, in comparison with the equation based from outlet air velocity. However, further study from various view points is necessary to conclude this issue.