年次大会講演論文集
Online ISSN : 2433-1325
会議情報
605 1700℃級ガスタービン用遮熱コーティングの劣化損傷評価
中山 真人久松 暢鳥越 泰治亀田 常治有川 秀行新田 明人藤井 智晴
著者情報
会議録・要旨集 フリー

p. 219-220

詳細
抄録
A high heat flux thermal testing apparatus using plasma was manufactured in order to evaluate the TBC's environmental resistance. The testing apparatus is able to control the composition of plasma gas. High heat thermal cyclic tests using air plasma with/without H_2O(g) were implemented for four kinds of the developed TBC (top coating; high purity YSZ(APS), ErSZ(APS), ScSZ(EB-PVD), La_2Zr_2O_7(APS)). Results of the thermal cyclic test have revealed that; (1) In the case of the top coating which has characteristics of low sintering resistance, temperature on the surface of the substrate was increased as cycled. (2) The presence of H_2O(g) influences the degradation and damage such as sintering behavior of the top coating and oxidation of the interface of the top coating/bond coating.
著者関連情報
© 2002 一般社団法人日本機械学会