年次大会講演論文集
Online ISSN : 2433-1325
会議情報
843 Sn-Ag-Cu 系はんだ BGA 接合部の疲労強度評価
寺崎 健長埜 浩太斉藤 直人
著者情報
会議録・要旨集 フリー

p. 439-440

詳細
抄録
Three different sizes of BGA (Ball Grid Array) solder joints were subjected to mechanical fatigue testing. It was found that the fatigue life of these joints strongly depends on their size and can be expressed by Coffin-Manson's law. In addition, Sn-3Ag-0.5Cu, Sn-1Ag-0.7Cu, and conventional Sn-37Pb BGA solder joints were also subjected to mechanical fatigue testing. It was found that the Sn-3Ag-0.5Cu joints had a fatigue life close to that of the Sn-37Pb joints. In contrast, the Sn-1Ag-0.7Cu joints had a fatigue life half as long as that of the Sn-37Pb joints.
著者関連情報
© 2002 一般社団法人日本機械学会