年次大会講演論文集
Online ISSN : 2433-1325
会議情報
1931 鉛ビスマス電磁流量計用電極材の腐食
三浦 邦明鬼沢 達也高橋 実
著者情報
会議録・要旨集 フリー

p. 277-278

詳細
抄録
A lead-bismuth alloy is promising as a coolant of the FBR and a spallation target material. An electromagnetic flow meter is used as a composition apparatus of that lead-bismuth testing device. As for the lead-bismuth, corrosion to the structure metal is a problem. Though stainless steel is the corrosion resistance metal, It was known that it corrode in the lead-bismuth of 500℃. Therefore, it is desirable to use it in less than 500℃. But, when temperature of lead-bismuth is less than 400℃, wettability of the lead-bismuth to the stainless steel get poor. The wettability of the electrode becomes unstable, too. Therefore, output of the EMF changes every time. The problem of the unstable wettability has already been solved by the Rh plating electrode. But, the Rh plating electrode, which improved wettability, has the possibility to make it produce the corrosion of the electrode. Therefore, we must evaluate rate of the corrosion about the Rh plating electrode. We soaked a Rh plating electrode into the melting lead-bismuth of 400℃, and rotated an electrode at a speed of 1m/s, and investigated the degree of the corrosion after the examination. As a result, after seventy-hour examination, 5μm corrosion was seen. After this, a long test will be done.
著者関連情報
© 2002 一般社団法人日本機械学会