1301 小型低比速度ポンプの高効率・高信頼性に関する研究
曹 銀春小林 秀嗣森川 晴彦藤田 知一古川 明徳
著者情報
会議録・要旨集 フリー

p. 1-2

詳細
抄録
It is well known that centrifugal pump efficiency becomes worse with the decrease of pump size and specific speed. The small-sized pump with low specific speed, in which the impeller outlet velocity was larger, was designed by an optimum design method combined with blade surface singularity method The results show as follows : The semi-open impeller designed by the optimum design method, yielded the highest efficiency of 61% among test impellers in narrow tip clearance c/b_2. In larger c/b_2,however, the leakage loss becomes dominant and the efficiency of impeller with larger blade outlet angle is higher. This fact implies that the c/b_2 should be considered as an additional factor for optimum design.
著者関連情報
© 2003 一般社団法人日本機械学会