Ni基自溶合金溶射部材の疲労特性に及ぼす再溶融処理方法の影響(S14-1 溶射材の疲労,S14 金属材料の疲労特性と破壊機構)
増田 伸光曙 紘之清水 真佐男
著者情報
会議録・要旨集 フリー

詳細
抄録
To clarify the relationship between fatigue properties and fusing methods, using vacuum furnace and induction heating system, rotational bending fatigue tests were performed on a medium carbon-steel(S35G) coated with thermally sprayed Ni-based self-fluxing alloy, under the condition of a fixed fusing temperature of 1010℃. As a result of these fatigue tests, the specimens fused by vacuum furnace (fusing time:30minutes to 10hours) did not show any delamination under cyclic loading. And a gradual reduction in fatigue strength was observed with the increase of fusing time. This is caused by the formation of inhomogenety in the coating layer with the increase of fusing time. On the contrary, the specimens fused by induction heating system(fusing time:200 seconds to 4hours)showed nearly the same fatigue strength as substrate did, because every specimen of these series showed delamination between substrate and coating layer. But formation of inhomogenety in the coating layer did not observed as specimens fused by vacuum furnace.