海底トンネルの入口急勾配部の排煙対応(G05-4 トンネルの排気・排煙・圧力・集じん,G05 流体工学部門一般講演)
加納 竜夫山本 邦夫
著者情報
会議録・要旨集 フリー

詳細
抄録
The Yumeshima tunnels are the immersed tunnels which connect between the reclaimed grounds at the Osaka harbor. As undersea tunnels, The inlets are steep downward slopes. It is quite likely that the smoke moves along the ceiling strongly to the stop vehicles side. It was asked for the exhaust wind velocity which suppresses ascension of smoke using CFD. In order to realize the wind velocity, It was devised connecting the duct of the ventilation station to the ceiling part of the lowest point of entrance of side box part.
著者関連情報
© 2004 一般社団法人日本機械学会