年次大会講演論文集
Online ISSN : 2433-1325
セッションID: 5017
会議情報
5017 水素充填時の高圧水素貯蔵容器内の温度挙動(S53 水素貯蔵技術における熱工学的諸問題,S53 水素貯蔵技術における熱工学的諸問題)
森本 収門出 政則Peter WOODFIELD光武 雄一
著者情報
会議録・要旨集 フリー

詳細
抄録
The increase in temperature of a gas has been measured during filling at a high pressure. Heat transfer between the compressed gas and the tank affects the strength of CFRP gas tanks which should be operated below 80℃. The experimental conditions are that filling gas is Hydrogen at 35MPa and at a filling mass flow rate of 50-180g/min. The temperatures are measured either vertically or horizontally at five positions in the tank. The characteristic of the gas temperature increase during filling and after filling are categorized into 4 regions. Coefficient of natural convective heat transfer is also given for different filling rates and for Hydrogen and Nitrogen.
著者関連情報
© 2006 一般社団法人日本機械学会
前の記事 次の記事
feedback
Top