The proceedings of the JSME annual meeting
Online ISSN : 2433-1325
VI.01.1
Session ID : F-1116
Conference information
F-1116 Non-Contact Strain-Controlled Fatigue Test with Digital Image Measurement System
Chaosuan KANCHANOMAIShinichi YAMAMOTOYukio MIYASHITAYoshiharu MUTOH
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
In a strain controlled low cycle fatigue test it is customary to use a contacting extensometer. However the extensometer can cause premature fracture at the contact points by inducing localized plastic deformation, particularly in a soft metal such as a lead-tin solder. In order to avoid this problem, a non-contacting, digital-image measurement system has been developed to measure the displacement of the specimen gage length during a cyclic loading. The capability of this system for strain-controlled fatigue testing was studied in preliminary experiments, and the effect of variables in the digital image measurement system on the accuracy and the reliability were established. Low cycle fatigue tests on three solder materials at 20℃ were then carried out using this system. The solders were: Ag-Sn eutectic solder (3.5Ag/96.5Sn), Sn-Pb eutectic solder (63Sn/37Pb) and Sn-Pb solid solution solder (5Sn/956Pb). The results confirmed that this system was capable of measuring the displacements in strain-controlled fatigue tests.
Content from these authors
© 2001 The Japan Society of Mechanical Engineers
Previous article Next article
feedback