抄録
A finite element model is used to study the transient thermo-elastic-plastic contact between a thermal asperity sensor and a thermal asperity. The temperature change of the thermal asperity sensor is determined during contact with an asperity. The results show that sensor temperature is a function of the operational temperature of the sensor and the friction coefficient between the sensor and the asperity.