M&M材料力学カンファレンス
Online ISSN : 2424-2845
セッションID: PS23
会議情報
PS23 オーステナイト系ステンレス鋼の高温高純水環境における応力腐食割れ発生挙動評価
剣持 明弘藤井 朋之東郷 敬一郎島村 佳伸
著者情報
会議録・要旨集 フリー

詳細
抄録
In this paper, constant tensile load tests under simulated primary water environment in boiling water reactor are carried out for sensitized stainless steel type 304 to evaluate influence of applied load and loading time on crack initiation and coalescence behavior by SCC. As a result, many stress corrosion cracks initiated is observed on the smooth surface of specimen, and coalescence of neighboring cracks is also observed. The number of cracks and crack length increase with increasing loading time and applied load. The crack length ranges from 0.02mm to 3.0mm. The crack length which is less than 0.1mm is normal-distributed, and the value of mean and variance of normally distribution are about 50μm and 17μm, respectively.
著者関連情報
© 2012 一般社団法人 日本機械学会