M&M材料力学カンファレンス
Online ISSN : 2424-2845
セッションID: OS1606
会議情報
OS1606 窒素イオン注入を施したTiNi形状記憶合金の熱・力学特性
武田 亘平戸伏 壽昭Levintant-Zayonts N.Kucharski S.
著者情報
会議録・要旨集 フリー

詳細
抄録
The nitrogen ion was implanted to TiNi shape memory alloy wires, and the influence of implantation treatment on the phase transformation temperature, tensile deformation and bending fatigue properties was investigated. The results obtained are summarized as follows. (1) If the dose of ion implantation increases, the reverse transformation temperature increases. (2) The larger the bending strain amplitude, the shorter the fatigue life is. If the strain amplitude is 4 %, the fatigue lives of all wires are almost the same. If the bending strain amplitude is small, the fatigue life becomes longer in the case of higher dose of ion implantation. (3) The fatigue crack nucleates at a certain point on the surface of the wire. In the case of higher ion implantation in the region of small strain amplitude, the fatigue crack initiation point differs from the maximum bending strain point, resulting in longer fatigue life.
著者関連情報
© 2013 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top