M&M材料力学カンファレンス
Online ISSN : 2424-2845
セッションID: OS1718
会議情報

骨移植に用いるゴムメタル製メッシュプレートの引張疲労特性に関する研究
*関口 航貴何 建梅
著者情報
会議録・要旨集 フリー

詳細
抄録

Recently in Japan, degenerative intervertebral discs have a sign of epidemic as one of diseases caused by aging and lifestyle habits. Degenerative intervertebral discs include lumber disc herniation, intervertebral disc herniation and cervical disc herniation. Currently practiced treatments called spinal fusion surgery using pure titanium or titanium alloy implant products have the problem that the loads on the natural-bone of the human body are large and will cause overloading on healthy nature bones. GUM Metal has characteristics of lower elasticity rigidity, large elastic deformation, higher strength and biocompatibility etc. When it is used for implant applications, there is still problem like overloading on the natural-bone because of its high rigidity compared with the human bones. Therefore, the purpose of this study is to create more flexible meshed plates for implant applications from the viewpoints of elastic rigidity and volume density. Basic mesh shapes are designed, devised and applied for meshed GUM Metal plates using three dimensional (3D) CAD tools. Experimental evaluation on tensile fatigue characteristics of meshed GUM Metal plate specimens are carried out. Analytical approaches on stress evaluation are also executed through finite element method to obtain the S-N curve for fatigue characteristic evaluation.

著者関連情報
© 2017 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top