直流電位差計測に基づく配管局部減肉の評価手法に関する研究
*武尾 文雄長利 颯大
著者情報
会議録・要旨集 認証あり

詳細
抄録

In this study, a simple method to evaluate the local pipe wall thinning by using the DC potential difference method was examined. The pipe has outer diameter D and thickness t0. The local inner-wall thinning is modeled as a back wall slot having arc-shape cross section of width 2w and depth b. The constant DC current is applied to the pipe through two probes, and the distribution of potential difference between current input and output probes is measured. The potential differences measured before and after thinning are represented as V0 and V1, respectively. The thinning depth b/t0 is evaluated from the maximum value of V1/V0. Three-dimensional finite element method was used to analyze the relation between thinning size and potential difference for various cases. As a result, it was shown that the relation between b/t0 and V1/V0 is affected by w/D. The calibration equation between b/t0 and V1/V0 was obtained by approximating FEM results, and its validity was shown by numerical experiments.

著者関連情報
© 2022 一般社団法人 日本機械学会