機械材料・材料加工技術講演会講演論文集
Online ISSN : 2424-287X
セッションID: 402
会議情報
402 オーステナイト系ステンレス鋼ろう付圧接継手の耐蝕性
池庄司 敏孝鈴村 暁男山崎 敬久山口 真秀
著者情報
会議録・要旨集 フリー

詳細
抄録
The braze-pressure-welding was conducted for the SUS316L and SUS304L austenitic steel pipes with various total heating time. The BPW's cleaning step was at 1280℃ with keeping time of 60-360s. The forging process was at 1180℃ with keeping time of 0-60s. For the cross section taken from the parts with distance of 0-20mm from the joint interface, the EPR tests were conducted EPR test was conducted to measure the degree of the sensitization of stainless steel. The cross section on the joint interface, the reactivation value was more than 10% indicating that part was sensitized, on the other parts, the values were lower than 1% and no sign of sensitization was suggested.
著者関連情報
© 2012 一般社団法人 日本機械学会