動力・エネルギー技術の最前線講演論文集 : シンポジウム
Online ISSN : 2424-2950
セッションID: A119
会議情報
A119 配管減肉試験での肉厚連続モニタリング手法の性能確認(検査・モニタリング-2(減肉関連),OS-6 保全・設備診断技術(2),一般講演,地球温暖化防止と動力エネルギー技術)
黒崎 裕一高木 愛夫浅野 恭一矢島 佐知子橋本 浩二
著者情報
会議録・要旨集 フリー

詳細
抄録
Recently, in the power plant piping, the wall-thinning problem by high temperature water and a two-phase flow (high temperature water and steam) attracts attention. Since the wall-thinning mechanism was not clarified, it is the purpose which understanding the mechanism of wall-thinning in plant, installed the piping corrosion test facility in which a long-term continuous test is possible, and started the wall-thinning examination of carbon steel piping. In addition, the ultrasonic sensor for high temperature, which can be measured in the state of the high temperature, was installed, and monitored wall thickness change during an examination period. For about two months, as a result of performing monitoring, the measured piping thickness was falling uniformly and checked that this monitoring system had caught the tendency of wall thinning. The difference of a monitoring result and the thickness measurement result after an examination was small. It identified that this monitoring system could accuracy monitoring also in high temperature.
著者関連情報
© 2008 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top