動力・エネルギー技術の最前線講演論文集 : シンポジウム
Online ISSN : 2424-2950
セッションID: A233
会議情報
A233 加圧水型原子炉の加圧器スプレー配管における温度変動現象の解明(OS2 保全設備診断技術(5))
石田 泰介三好 弘二杉本 勝美竹中 信幸
著者情報
会議録・要旨集 フリー

詳細
抄録
Gas liquid interface is formed in a pressurizer spray pipe of a pressurized water reactor when flow rate is small at normal reactor operation. Temperature fluctuation may occur if the interface moves periodically. Measurement of inner wall and fluid temperature in the test section simulating the real pressurizer spray pipe was conducted to study mechanism of the temperature fluctuation phenomena. The effect of non-condensable gas was investigated by injecting helium gas into test section. When helium gas was injected, the condensation of the vapor was suppressed and the temperature fluctuation was reduced. Richardson number increases with the helium gas injection, which is higher than 0.25 in all conditions of the present experiment. Brunt Vaisala frequency nearly equal to the peak of temperature power spectral density. It seemed that the internal gravity waves caused temperature fluctuations in water layer below the interface.
著者関連情報
© 2014 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top