動力・エネルギー技術の最前線講演論文集 : シンポジウム
Online ISSN : 2424-2950
セッションID: D131
会議情報

蒸気配管におけるクランプオン式超音波流量計測
佐々木 宏林 智仁梅沢 修一
著者情報
キーワード: clamp-on, ultrasonic, flow, flowmeter, steam, pipe
会議録・要旨集 フリー

詳細
抄録

A clamp-on ultrasonic gas flowmeter we had developed has been modified to measure steam flow by developing new damping material endurable to high temperature. With this flowmeter, the flow of steam at 0.7MPaG in the pipe of 50A SGP can be measured up to 30m/s flow rate. This measurement is reproducible. The flowmeter is compatible to both saturated steam and superheated steam. The key of this success depends on the newly developped damping material. The base material effectively dump the high frequency ultrasonic was explored widely. Dense material was added to increase the acoustic impedance. We are now trying to lower the measurable steam pressure and widen the target pipes.

著者関連情報
© 2016 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top