動力・エネルギー技術の最前線講演論文集 : シンポジウム
Online ISSN : 2424-2950
2017.22
セッションID: C134
会議情報

クランプオン型超音波流量計による湿り蒸気流量の計測
*森田 良内山 雄太梅沢 修一杉田 勝彦
著者情報
会議録・要旨集 フリー

詳細
抄録

In industrial fields, as the steam is commonly utilized for heat supply, drying process and so on, it is important to be aware of the steam flow rate in the view point of energy management. However, the steam utilized in the factory is usually wet steam condition. Though it is well known that the wetness affects the flowmeter reading, it is difficult to clarify the effects of the wetness in the steam flow quantitatively in actual plants and factories, and thus far, there has been no established method for estimating the error caused by the wetness of steam flow. This research introduced the characteristics of the clamp-on type ultrasonic flowmeter both in dry steam flow and in wet steam flow experimentally, which an additional work is not necessary to the piping. Ultrasonic flowmeter reading was compared with Coriolis flow meter installed after heat exchanger in the steam apparatus. As a result, we clarified the flow rate difference of those two flowmeters was increased with increasing wetness.

著者関連情報
© 2017 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top