動力・エネルギー技術の最前線講演論文集 : シンポジウム
Online ISSN : 2424-2950
セッションID: D134
会議情報

再生可能エネルギー導入時の火力発電の調整力評価に関する研究
(調整力の指標を用いた石炭火力の低負荷運用性能と追加コストの評価)
*吉葉 史彦花井 悠二渡邊 勇白井 裕三
著者情報
会議録・要旨集 フリー

詳細
抄録
This report sorts out the indices of performances and additional expenditures of power balancing operation of thermal power plant during the massive introduction of intermittent renewable energies. The efficiency of the 700MW class coal fired power plant during the partial load operation and throttle valve control operation is calculated by the material and heat balance analysis; the calculated efficiency is applied to the basic performance of the coal fired power plant in the demand – supply balance analysis. By applying the indices of the low load LFC, Load Frequency Control, performance the demand- supply balance of the supposed balancing group (IEEJ standard model, AGC30 model) is analyzed. In the case that the coal power plant is operated within the low load condition, LFC ability is performed by the throttle control operation; the throttle control is responsible for the possible failure of the plant. The expenditure of substituting the failure of LFC of coal plant is calculated. The substitution by the LNG steam cycle plant consumes much amount of fuel gas compared to the case that the GTCC is selected as the substitution.
著者関連情報
© 2019 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top