抄録
A pulse train analysis is reported here from the viewpoint of both a hardware and a software.In hardware part, an interface board is specifically designed which can administer the height and the timing of the pulses of a pulse train.The front-end of the hardware system is a Wilkinson-type ADC. The crude data taken in by the hardware are pulse height and arrival time of respective pulses.The software part reconstructs the data into pulse height distribution, time interval distribution, count rate representation, direct representation of pulses along the time elapsed, frequency distribution f (n) of pulse count n, and such statistical moments as μ, σ, S, K of f (n). Statistical tests can be practiced as well. The system is actually applied to the anticipation of magnet relay breakdown.