The Proceedings of JSME annual Conference on Robotics and Mechatronics (Robomec)
Online ISSN : 2424-3124
2013
Session ID : 1P1-O06
Conference information
1P1-O06 Simultaneous local ablation and injection into cell by electrically-induced micro-bubble knife(MEMS and Nano-Technology)
Hiroki KURIKIYoko YAMANISHIShinya SAKUMATakamasa SUZUKITetsuya HIGASHIYAMAFumihito ARAI
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
For the present study, simultaneous ablation and injection were successfully operated by using electrically-induced micro-bubble knife. The novelty of the present techniques are (1) dispensing of micro-bubble can penetrate and make an ablation of a cell wall by the cavitation of micro-bubble in bubble reservoir and (2) the reagent was successfully introduced to the interface of the bubble surface. In this paper we demonstrate transportation of micro-bubble with methylene blue and simultaneous ablation of BY-2 cell wall and injection of fluorescent particles whose diameter were 2.1 μm. It means that electrically-induced micro-bubble knife has the possibility to gene transfer for the versatile use and can be contribute to gene engineering.
Content from these authors
© 2013 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top