Host: The Japan Society of Mechanical Engineers
Name : [in Japanese]
Date : June 01, 2022 - June 04, 2022
We developed two types of non-wearing power assist devices that allow the squat method. One is a pneumatic power assist device that uses a pneumatic actuator, the other is a passive power assist device that uses only springs. The support effect and muscle burden over time were evaluated using EMG and floor reaction force through lifting motion support experiments for these devices. From the experiment result, it was confirmed that the muscle burden on the lower body of the subject were significantly reduced, which prove the effect on one-side support using both non-wearing assist device.