スターリングサイクルシンポジウム講演論文集
Online ISSN : 2424-2926
セッションID: B02
会議情報
B02 3次元CADを用いたスターリング冷凍機のクリアランス解析(スターリング冷凍機)
阿部 紘一良大高 敏男関谷 洋大田 正廣
著者情報
会議録・要旨集 フリー

詳細
抄録
This paper presents a clearance Analysis using 3D-CAD system on a Stirling refrigerator. A prototype Stirling refrigerator employing helium as a working fluid has been investigated to see whether the freon free machine be a viable alternative for the current household refrigerator. It is modify to the most suitable working space by reducing a dead volume. But the working space is a complex form because, the working space composes a displacer and a compression piston. Using 3D-CAD system does the modeling of a Stirling refrigerator. And it is made that a clearance in each part becomes proper. The displacer form and an inside cylinder were modified. These results reveal that the dead volume can reduce about 10.28 m^3 And a theory cooling capacity may improvement about 28.41 W.
著者関連情報
© 2001 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top