The Proceedings of the Symposium on Stirlling Cycle
Online ISSN : 2424-2926
2001.5
Session ID : C01
Conference information
C01 Effects of Stacking Method on Heat Transfer Characteristic in Stacked Wire Gauze (2nd Report)
Yohei MAGARAKazuhiro HAMAGUCHIIwao YAMASHITA
Author information
CONFERENCE PROCEEDINGS FREE ACCESS

Details
Abstract
The regenerator is the regenerative heat exchanger, which greatly influences the performance of the Stirling cycle machines. A stacked wire screen of which a balance of flow loss and heat transfer characteristics is good, is often utilized for this regenerator matrix. The stacking method of the wire gauze is a method for perpendicularly stacking for the flow of the working gas. Therefore, the basic characteristic of stacked wire gauze reported until now, was only perpendicular stacked wire gauze. However, the method stacking parallel to the flow of the working gas is also considered. In this study, in order to grasp the basic characteristics of parallel stacked wire gauze, the effect of the stacking method on basic characteristic is examined experimentally. The effect on the pressure loss examines experimentally in the previous report. So, the superiority of the parallel stack wire gauze has been confirmed. In this paper, the effect of the stacking method on Nusselt number is examined experimentally. And, the friction factor and Nusselt number of two type stacked wire gauze are compared.
Content from these authors
© 2001 The Japan Society of Mechanical Engineers
Previous article Next article
feedback
Top