スターリングサイクルシンポジウム講演論文集
Online ISSN : 2424-2926
セッションID: C05
会議情報
C05 蓄熱器内のエネルギー変換の直接観測(パルス管冷凍機,熱音響機器及び関連要素と応用システム(2))
田代 雄亮琵琶 哲志矢崎 太一
著者情報
会議録・要旨集 フリー

詳細
抄録
In this paper, we report the direct observation of the energy conversion in a narrow tube having a temperature gradient. A gas parcel in the tube was driven by an oscillating piston at 1.00Hz to assure good thermal contact with the tube wall. We measured the oscillations of pressure and velocity in the tube to determine the acoustic intensity in the tube. We observed the amplification of the acoustic intensity in the region having a positive temperature gradient. We derived specific volume oscillation of the gas parcel from the measured pressure and temperature. The increase of the acoustic intensity per unit length was in good agreement with the enclosed area in the plot of pressure versus specific volume. This represents that the amplification of the acoustic intensity results from the thermodynamic cycles experienced by the gas parcel.
著者関連情報
© 2006 一般社団法人 日本機械学会