スターリングサイクルシンポジウム講演論文集
Online ISSN : 2424-2926
セッションID: D02
会議情報
D02 ホットワイヤセンサを用いた圧縮・膨張時の気体温度測定(再生熱交換器の基本特性)
太田 益隆原村 嘉彦
著者情報
会議録・要旨集 フリー

詳細
抄録
Heat transfer during compression and expansion is particularly important in closed-cycle machines such as Stirling engines and pulse-tube refrigerators. It is important to know the temperature profile near the wall by which the heat transmission is determined. The early work measured temperature profile near the wall with a thin (3.8μm diameter) hot-wire censer. But, the measured temperature was affected by the supports of hot-wire censer. Therefore, the effects of supports calculated using control volume method. The parameter of the equation is only the angular frequency divided by the thermal diffusivity, and it is possible to correlate with this value. In the results, dimensionless temperature and the average temperature amplitude of the censer were estimated.
著者関連情報
© 2006 一般社団法人 日本機械学会