C03 矩形パルス管冷凍機内ガス流動の可視化(パルス管冷凍機,熱音響機器及び関連要素と応用システム(1))
齊藤 剛寺崎 智濱口 和洋
著者情報
会議録・要旨集 フリー

p. 43-44

詳細
抄録
The working gas flow in a rectangular pulse tube refrigerator was visualized using the Schlieren technique in order to understand characteristics of a gas piston. The experiments were conducted with inertance tube lengths of 700mm, 1350mm, 2100mm. One side of the gas piston end that was the boundary of a jet from a regenerator was observed. The lowest cool-down temperature was -19℃ at the condition of the inertance tube length 1350mm. At this condition, it was found that the gas piston end was just reached at the regenerator when the direction of a compression piston was changed from expansion to compression.