スターリングサイクルシンポジウム講演論文集
Online ISSN : 2424-2926
セッションID: A13
会議情報
A13 熱音響エンジンにおける濡れたスタック内の温度分布の測定(再生器)
若崎 真吾上田 祐樹秋澤 淳
著者情報
会議録・要旨集 フリー

詳細
抄録
The onset temperature of the thermoacoustic engine is required to bring down in respect of utilizing waste heat. Tsuda reported that the onset temperature is 343K when water vapor exist in the thermoacoustic engine. However it does not investigate the influence that adding water vapor gives in the temperature distribution in the stack of the thermoacoustic engine. In this study, we measured the temperature distribution in the stack of the thermoacoustic engine having wet stack after drive was starting and stable. The result of this experiment indicates that the temperature distribution in the wet stack becomes the curve of the convex.
著者関連情報
© 2015 一般社団法人 日本機械学会