熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: D114
会議情報
マイクロセンサによるプール沸騰高熱流束域での液層ドライアウト挙動(一般セッション 相変化 I)
小野 綾子坂下 弘人
著者情報
会議録・要旨集 フリー

詳細
抄録
Dryout process appearing near critical heat flux for water boiling on an upward heating surface was investigated with conductance probes with tip diameter below 5μm. 2-D distribution of dryout void fraction was obtained by analyzing the dryout signals which were measured at 3〜5μm above the heating surface at 121 grid points in an area of 1×1[mm^2]. It was found that the dryout void fraction increased rapidly near critical heat flux and the dryout occurred in specific area of the heating surface. The liquid layer thicknesses were estimated based on the time from formation of vapor mass to start of dryout. and agreed well with the previously reported thicknesses which was determined from the height at which the vapor mass signal disappear.
著者関連情報
© 2004 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top