熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: F151
会議情報
F151 間欠的熱輸送ループの作動限界物理モデル(一般セッション 熱交換器)
角口 勝彦上山 愼也
著者情報
会議録・要旨集 フリー

詳細
抄録
The effect of the non-condensing vapor bypass flow and the amount of the working liquid was experimentally investigated on the operating limit of the originally proposed method for heat transportation by utilizing the intermittent discharge of the accumulated high-pressure vapor. The analytical result for finding the condition at the occurrence of the operating limit was shown by taking a proposed physical model into account. The condition could be estimated quantitatively by using a proposed new non-dimensional parameter.
著者関連情報
© 2005 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top