熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: F155
会議情報
F155 平滑管群潜熱回収熱交換器の性能特性に関する研究(一般セッション 熱交換器)
増井 雄介浅野 等山本 達也堀 紀弘
著者情報
会議録・要旨集 フリー

詳細
抄録
In order to improve thermal efficiency of a gas water heater, an additional heat exchanger is required for latent heat recovery from the exhaust gas. In this study, two types of smooth-tube bank heat exchanger with a staggered and inline tube arrangement were installed to a commercial hot water heater with the output of 34.8kW, and the performance was evaluated under a normal using condition. The experimental results were compared with numerical results by a model based on the analogy between heat and mass transfer. The tested heat exchanger satisfied the required performance, which is a thermal efficiency of 89% based on HHV. Experimental results of heat transfer rate showed higher values than the numerical results, though those of condensing rate showed lower values.
著者関連情報
© 2005 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top