D124 臨界圧近傍における二酸化炭素の水平管内強制対流熱伝達(混相流2)
山本 拓植田 裕也石原 勲小澤 守梅川 尚嗣松本 亮介
著者情報
会議録・要旨集 フリー

詳細
抄録
In this study, the experimental apparatus is set up using a horizontally placed 2mm diameter tube to measure the heat transfer coefficient and pressure drop of carbon dioxide near critical pressure (reduced pressures are adjusted from 0.81 to 0.91). The mass fluxes are controlled from 200 to 500kg/m^2s. In higher-pressure region, the dryout starts at lower quality on top of the tube, and then the boiling heat transfer coefficient decreases gradually. In addition, its flow pattern is observed at 5.0MPa too. A typical flow patterns are confirmed with carbon dioxide flow even in 2mm diameter tube.