Abstract
This paper summarizes the results of our researches that we have performed to clarify the mechanism of critical heat flux (CHF) for saturated and subcooled pool boiling on an upward surface with high heat capacity. The reasons why the macrolayer dryout model would be the most appropriate model for the CHF are presented. A macrolayer formation model applicable to both saturated and subcooled boiling is also introduced.