G113 水素ステーションにおけるプレクール装置の出口温度・圧力の推定(一般講演)
田中 誠一門出 政則渡辺 昇
著者情報
会議録・要旨集 フリー

詳細
抄録
During rapidly filling of hydrogen gas at high pressure into a FCV tank, temperature of hydrogen gas in the tank suddenly rise resulting into a rise in the tank wall. The regulation of safety requires the temperature of hydrogen gas lower than 85℃. Filling system using precooled hydrogen is proposed to reduce the temperature rise of hydrogen gas in the tank. For the practical design of the precooling equipments, a simplified thermodynamic analysis has been done for operation of filling hydrogen gas by considering heat transfer in the equipments. The calculated conditions of hydrogen gas at outlet agreed with the measured ones.
著者関連情報
© 2010 一般社団法人 日本機械学会