熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: C111
会議情報
C111 ボルテックスジェネレータを用いた伝熱促進 : 渦構造と熱伝達の関係(OS-7:電子機器における熱流動現象(I))
谷 彰太川口 清司五十嵐 隼渡辺 大輔
著者情報
会議録・要旨集 フリー

詳細
抄録
Heat transfer enhancing method is more and more needed to decrease power consumption. This study was carried out to develop a high performance vortex generator, and find out the relationship between vortex structure and heat transfer. Double delta winglet pair was developed to reduce pressure drop with keeping up vortex strength. It was clarified that double delta winglet pair had higher performance than delta winglet pair by 10% at flow velocity of 1.4m/s by measuring average heat transfer coefficient and pressure drop. It was found out that double delta winglet pair had the position of vortex core at short distance from heat transfer surface than delta winglet pair. Therefore, the heat transfer coefficient was larger than delta winglet pair's one, even though it's vortex strength was smaller than that.
著者関連情報
© 2010 一般社団法人 日本機械学会