熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: A121
会議情報
A121 CO_2冷媒のキャピラリーチューブ内減圧沸騰流に関する研究(OS-7:次世代ヒートポンプ・冷凍システム(2))
小林 建太浅野 等Abo-Efadl Saleh滝口 浩司土屋 敏章石田 真
著者情報
会議録・要旨集 フリー

詳細
抄録
This paper deals with decompression flashing flows through an adiabatic capillary tube with inlet subcooling and supercritical conditions. Blowdown experiments were carried out for a horizontal copper straight tube with the inner diameter of 0.7 mm and the length of 1000 mm. Boiling inception points were measured form wall temperature profiles, and critical mass flow rates were measured. The condition when a flow became to critical flow was specified by changing the exit pressure. As the results, for the inlet subcooling conditions, a boiling delay with thermal non-equilibrium around the boiling inception point was not observed. In this case, measured temperature profiles agreed well with numerical calculation results based on homogenous model.
著者関連情報
© 2012 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top