熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: E123
会議情報
E123 エンジン式超高圧パルス殺菌試験装置の水圧発生特性(一般講演(6))
紺野 隼鈴木 実
著者情報
会議録・要旨集 フリー

詳細
抄録
Ultra high pressure underwater shock waves were applied to the sterilization of microbes. We used the imploding detonation of propane-oxygen to occur the ultra high pressure underwater shock waves. We investigated the imploding detonation using an engine type liquid sterilization apparatus having a precombustion chamber and two sample holders with inner volume of 5L. This apparatus can work 60〜90 rpm continuously and sterilize the water of 20m^3/h. We investigated the pressure of underwater shock waves relation with engine speed and supplied pressure. We found that we could generate about 40〜60 MPa underwater shock waves in the sample holders.
著者関連情報
© 2013 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top