熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: F131
会議情報
F131 定常熱流法を用いた水素吸蔵合金の熱特性計測(OS-8:熱物性・計測(2))
伊東 浩介藤野 貴康前田 哲彦
著者情報
会議録・要旨集 フリー

詳細
抄録

The present paper discusses the validity of experimental apparatus for measuring the effective thermal conductivity of metal hydride by the steady heat flow method. We measured the thermal conductivity of Polyacetal whose thermal property is already known to confirm the validity of experimental apparatus. The average value of experimental results is 0.31 W/m-K. The difference between this value and the literature data of 0.23 W/m-K is 10^<-2> order, so that the measuring accuracy of experimental apparatus is sufficiently high. The reproducibility of experimental results is sufficient since the maximum difference among the experimental results is only 0.06 W/m-K under the same condition. The results obtained in our experiments indicated that the experimental apparatus is reliable as the measurement apparatus of effective thermal conductivity of metal hydride.

著者関連情報
© 2013 一般社団法人 日本機械学会