熱工学コンファレンス講演論文集
Online ISSN : 2424-290X
セッションID: A131
会議情報
A131 制限換気プール火災の火源極近傍熱流動の構造特性(OS-1:火災安全・燃焼(2))
服部 康男松山 賢須藤 仁大沼 英司沖永 誠治
著者情報
会議録・要旨集 フリー

詳細
抄録
We have experimentally investigated a ventilation-controlled and medium-size pool fire (fuel: ethanol). Special attention was paid to meandering processes with the low frequency velocity fluctuations in the vicinity of a pool, which were revealed by our previous study. The velocity vectors were measured by using a PIV technique with spores of lycopodium clavatum as tracer particles (the diameter becomes several μm in flame). The dominant flow structures, which were obtained by the proper orthogonal decomposition with measured velocity vectors, clearly show the impacts of under ventilation conditions: the deficient O2 supply yields suppression of puffing motions and activation of leisured fluid motions in horizontal direction.
著者関連情報
© 2013 一般社団法人 日本機械学会
前の記事 次の記事
feedback
Top