509 床構造の温水式床暖房及び床冷房の放熱特性及び冷却特性への影響(GS-8 熱(2))
佐々木 寛千葉 智徳安原 薫横山 孝男菊地 薫
著者情報
会議録・要旨集 フリー

詳細
抄録
The object of this study is improvement of floor heating in the quality of thermal storage and heat release and floor cooling without changing specification. Outdoor facility experiment which consists of 4 kinds of floor structure prototypes (Concrete burial, Panel cell, Charcoal+Insulation and Charcoal) were tested about thermal storage/release performance. Characteristics of heat transfer of Panel cell were also tested in the temperature-controlled room. Moreover, floor cooling using conventional floor heating system is tried in the model house. The results show that the Panel cell is superior to charcoal in performance and floor cooling system can be operated.