414 表層欠陥検出用超音波センサの開発 : 溶射皮膜評価への適用
山本 弘瀧下 芳彦山本 明彦
著者情報
会議録・要旨集 フリー

p. 265-266

詳細
抄録
This paper is concerned with the development of Ultrasonic probe for detecting near surface discontinuity. Near surface discontinuity is difficult to detect for ultrasonic testing. To detect near surface discontinuity, a leaky surface acoustic wave (LSAW) experiment is carried out. But ordinarily it is difficult to separate the LSAW and the longitudinal waves along the central axis. In this study, a hollow is made in the center of the acoustic lens, and so the separation of LSAW becomes possible. The lens is named DH (Delaying Hole) lens. To verify the effect of the lens, the delamination and crack test samples are made, and sprayed coating surface are evaluated at the condition that surface are un-machined. The results show that with this method, delamination and crack parts are clearly detected and the acoustic image near the edge parts can also be clearly obtained.
著者関連情報
© 2000 一般社団法人日本機械学会