材料力学部門講演会講演論文集
Online ISSN : 2433-1287
会議情報
119 ArFRP の疲労破壊挙動に及ぼす応力波形と水環境効果
駒井 謙治郎箕島 弘二田中 和人徳良 具巳
著者情報
会議録・要旨集 フリー

p. 97-98

詳細
抄録
The influences of stress waveform and water absorption on the tension-tension fatigue fracture behavior were investigated using aramid fiber/epoxy matrix unidirectional composite (Kevlar49/#2500). The fatigue tests were performed for specimens preconditioned in dry air (dry specimen) and the ones that were immersed in deionized water at 80℃ (wet specimen). Negative and positive pulse waveforms were used for fatigue tests. For dry specimens, the fatigue strength under negative pulse waveform was lower than that under positive pulse waveform. At a high stress level, the fatigue strength under positive pulse waveform became hardly independent of applied stress, and therefore the S-N curve became flat. The fatigue strength of wet specimens was lower than that of dry specimens at high stress level. The fracture surface was closely examined using a scanning electron microscope (SEM).
著者関連情報
© 2000 一般社団法人日本機械学会
前の記事 次の記事
feedback
Top