材料力学部門講演会講演論文集
Online ISSN : 2433-1287
セッションID: 608
会議情報
608 ボルト締め管フランジの締付け手順の検討(OS2-1 フランジガスケット締結体の力学と密封性能評価,OS2 フランジガスケット締結体の力学と密封性能評価3)
熊倉 進正司 康雅本間 和弘細矢 裕彦
著者情報
会議録・要旨集 フリー

詳細
抄録
Generally, a bolt axial tension is applied by the torque control method for the bolted flange connection. The torque control method does not allow an accurate control of the bolt axial tension due to the problems related to friction. Another cause is that the axial tensions of bolts often do not become uniform because tightening of bolts causes elastic interaction among bolts, when more than one bolts are used. In order to obtain uniform bolt loads and to prevent accidents, a guideline of the pipe flange tightening was proposed by ASME PPC-1. However, the easier tightening method is desired for more than it. In this study, FEM analyses and correspond experiments were examined, and the authors propose to tighten two bolts simultaneously in the bolted flange connection sequence.
著者関連情報
© 2005 一般社団法人日本機械学会
前の記事 次の記事
feedback
Top