材料
Online ISSN : 1880-7488
Print ISSN : 0514-5163
ISSN-L : 0514-5163
高静水圧下の引張圧縮疲労試験装置の試作とこれによる二, 三の実験
大路 清嗣小倉 敬二杉本 一雄家治 敬一
著者情報
ジャーナル フリー

1972 年 21 巻 227 号 p. 772-777

詳細
抄録
A push-pull fatigue testing machine under high pressure up to 6000kg/cm2 was developed. Using this machine, the preliminary fatigue tests in the low-cycle fatigue range were conducted under the load-cycling conditions with OFHC copper, 5005 Al alloy and S35C carbon steel under hydrostatic pressures up to 4000kg/cm2. The unnotched fatigue strength showed a slight but definite increase with increasing ambient pressure. No discernible difference was observed in the notched fatigue strength of OFHC copper between 0 and 3000kg/cm2 ambient pressure. The scanning electron fractograph of unnotched OFHC copper specimens revealed no apparent difference in the striated regions of fatigue-fractured specimens under 3000kg/cm2 and zero ambient pressure.