デモクラティックモジュール光発電システムによるフィールドテスト(FT)実証評価
高倉 秀行藤井 剛濱川 圭弘
著者情報
ジャーナル フリー

2001 年 50 巻 4 号 p. 380-382

詳細
抄録
A systematic investigation has been made on generated electric energy from different photovoltaic (PV) solar arrays consisting of three kinds of silicon based solar cells. Clarification of seasonal output power variations with temperature in c-Si and a-Si cells might be important issue for the operations of PV system. It has been shown from the results that output power from a-Si array is 20% larger than that from c-Si in summer. On the other hand, in winter, this scene should be reverted. However output power from c-Si array is only 5% larger than that from a-Si. The analyzed data also show that annually accumulated electric energy generated from a-Si array corresponds to 90% of its nominal efficiency in the year. While in case of c-Si array, this ratio is about 84%.