7年間海岸に暴露した鉄筋コンクリート試験体への交流インピーダンス法を用いた鉄筋腐食検査手法の適用
松村 卓郎金津 努西内 達雄
著者情報
ジャーナル フリー

2002 年 51 巻 5 号 p. 581-586

詳細
抄録

The applicability of non-destructive corrosion detection using AC impedance method to the specimens is investigated, in which test specimens have been exposed to seashore environment for seven years at three different sites, Matsumae in Hokkaido, Nagoya and Ishikawa in Okinawa. The followings are main conclusions derived from the tests results: a) Steel corrosion in concrete and cracks in concrete cover due to steel corrosion were observed after seven years exposure. Steels in the specimens exposed to tidal condition in Nagoya corroded considerably. On the other hand, steels in the specimens exposed to seaside area in Matsumae and Okinawa corroded a little. b) The corrosion detection technique using AC impedance method can be well used to estimate amounts of steel corrosion of specimens irrespective of environmental conditions.